hytos / DTI_PID / SPPIDConverter_CustomCommand / temp / mapping.xml @ 22adf874
이력 | 보기 | 이력해설 | 다운로드 (2.58 KB)
1 | 16dabf13 | gaqhf | <?xml version="1.0" encoding="utf-8"?>
|
---|---|---|---|
2 | <Mapping>
|
||
3 | <Symbol>
|
||
4 | <DATA SPPID="\Piping\Piping OPC's\KRP Off-Drawing.sym">KRP Off-Drawing</DATA> |
||
5 | <DATA SPPID="\Piping\Labels - Piping Segments\Kemya Line Number.sym">Line Number</DATA> |
||
6 | <DATA SPPID="\Piping\Labels - Piping Components\Nominal Diameter.sym">Piping Component Nominal Diamiter Label</DATA> |
||
7 | <DATA SPPID="\Piping\Fittings\Spectacle Blanks and Spacers\Closed Spectacle Blind.sym">Spacer Blind</DATA> |
||
8 | <DATA SPPID="\Piping\Fittings\Diameter Change\Concentric.sym">Concentric</DATA> |
||
9 | <DATA SPPID="\Design\Annotation\Labels\Item Note & Label.sym">NOTE</DATA> |
||
10 | <DATA SPPID="\Design\Annotation\Labels\Item Note & Label.sym">TEXT</DATA> |
||
11 | <DATA SPPID="\Piping\Valves\2 Way Common\Gate Valve.sym">Gate Valve</DATA> |
||
12 | <DATA SPPID="\Piping\Routing\Process Lines\Primary Piping.sym">Primary</DATA> |
||
13 | <DATA SPPID="\Instrumentation\Signal Line\Connect to Process.sym">Connect To Process</DATA> |
||
14 | <DATA SPPID="\Instrumentation\Signal Line\Electric.sym">Electric</DATA> |
||
15 | <DATA SPPID="\Instrumentation\Actuators\Diaphragm Actuator.sym">Actuator with handwheel</DATA> |
||
16 | <DATA SPPID="\Instrumentation\In-Line\Valves\2 Way Common\2 Way Ball.sym">2-Way Angle Globe Valve</DATA> |
||
17 | <DATA SPPID="\Instrumentation\Relief Devices\Press Relief Valve.sym">Angle Valve</DATA> |
||
18 | <DATA SPPID="\Piping\Valves\2 Way Common\Butterfly Valve.sym">Butterfly Valve</DATA> |
||
19 | <DATA SPPID="\Instrumentation\In-Line\Valves\3 Way\3 Way Generic Body.sym">3-Way Instrument Root Valve</DATA> |
||
20 | <DATA SPPID="\Instrumentation\Labels - General Instrument\Nominal Diameter.sym">Instrument Nominal Diamiter Label</DATA> |
||
21 | <DATA SPPID="\Instrumentation\System Functions\D C S\Clone of DCS Func Access in Prime Loc(1).sym">Disc Single-Func Field Mounted</DATA> |
||
22 | <DATA SPPID="\Instrumentation\Off-Line\Without Implied Components\Single Function\Clone of Disc Single-Func Field Mounted(2).sym">Disc Single-Func Access in Aux Loc</DATA> |
||
23 | <DATA SPPID="\Instrumentation\System Functions\Interlocks\_Interlock Function -2.sym">Disc Single-Func Inaccess in Prime Loc</DATA> |
||
24 | <DATA SPPID="\Equipment\Vessels\Horizontal Drums\1to1Parametric H Drum.sym">Compressor</DATA> |
||
25 | <DATA SPPID="\Piping\Valves\2 Way Common\Ball Valve.sym">Ball Valve</DATA> |
||
26 | </Symbol>
|
||
27 | <Attribute>
|
||
28 | <DATA SPPID="NominalDiameter">NominalDiameter</DATA> |
||
29 | <DATA SPPID="PIPINGMATERIALSCLASS">PipingMaterialsClass</DATA> |
||
30 | <DATA SPPID="INSULPURPOSE">InsulationPurpose</DATA> |
||
31 | <DATA SPPID="MEASUREDVARIABLECODE">Type</DATA> |
||
32 | <DATA SPPID="TAGSEQUENCENO">SeqNumber</DATA> |
||
33 | </Attribute>
|
||
34 | </Mapping> |